Standard Power Quality Disturbance Generators
PSL's Industrial Power Corruptors generate bad quality power, reliably and repeatedly. Use an IPC to test sensitive systems, making sure your design will work when it is installed. These are the best instruments for complying with SEMI F47, SEMI E6, IEC 61000-4-11, IEC 61000-4-34, and other international standards. Easy-to-use Windows software included
Why You Need an Industrial Power Corruptor
Creates voltage sags, swells, and interruptions for testing industrial equipment immunity.Use to test equipment rated at up to 200 amps. The standard generator for equipment certification: SEMI F47, IEC 61000-4-11, IEC 61000-4-34.Built-in 29-channel digital oscilloscope recorder. Optional power flow recorder for SEMI E6, too. |
|
Simple and Intuitive Disturbance controls.Amplitude, duration, angle of sags can be adjusted manually.Or you can select one of the many built-in standards. The Test Margin button lets you select a design margin for your testing. Once you're set, just arm and fire the event! |
|
AC power comes through the left, and goes out at right to the load.Just break a power cable, and insert the Industrial Power Corruptor - with standard accessories, it can accomodate wires from 18AWG to 00.Every IPC works with single-phase, three-phase delta, and three-phase-wye (star) systems. |
|
Exclusive safety featuresAvailable only in the Industrial Power Corruptor - user-adjusted trip current (far left), and knob-selected disturbed phase, optimized for SEMI F47, IEC 61000-4-11, and IEC 61000-4-34. |
|
Another safety featureCritical switches have mechanical shields, preventing accidental operation.And any current flowing through any of the IPC earth connections (not shown) trips the main circuit breaker - another safety feature. |
|
Modular and CustomizableThe Industrial Power Corruptor is highly modular, making repairs and upgrades easy.The IGBT (insulated gate bipolar transistor) module is highlighted at left. This module uses 1200 volt, 600 amp bipolar transistors to perform precision power transitions. |
|
Semiconductor tool manufacturers...
Semiconductor tool Manufacturers and their component suppliers, use the Industrial Power Corruptor to comply with SEMI F47, which increases reliability, and SEMI E6, which improves energy consumption.University and national research labs...
University and national research labs use the Industrial Power Corruptor for research projects, and to run critical equipment for large experiments through voltage sags and swells. Typical standards include IEEE 1100 (CBEMA).
Industrial engineers...
Industrial engineers use the Industrial Power Corruptor to verify that new electronic equipment will tolerate voltage sags and swells, and to find out if voltage sag correction devices work properly.
IPC Software
![]() The Industrial Power Corruptor software package runs on any Windows® computer (Windows 95®, Windows 98®, Windows 2000®, Windows NT®, and Windows XP®), including DBC versions for Asian languages. Delivered on a CD-ROM, the software package manages most of the IPC operation. However, critical timing applications are handled by the five processors inside the IPC, and, for safety reasons, all power events are controlled from switches on the IPC. |
|
The 28-channel data acquisition system in every Industrial Power Corruptor helps you solve any problems in your equipment.Zoom in and out, sunchronize channels, convert waveforms to RMS, and more. The example above shows a DC power bus (top graph) that has been affected by a voltage sag (middle graph). Other graphs (not shown) let you examine currents and more voltage channels. No need to hook up dangerous voltage leads or current clamps to your AC lines - they're all automatically sensed inside the IPC. |
|
The IPC Software helps you document every aspect of your testing - great for writing reports later on! |
|
Power Flow OptionYou can use the real-time Vector Scope to examine phase rotation, unbalance, and more. The Power Flow Option also gives you real-time oscilloscopes and spectrum analyzers - great for tracking down harmonics problems. |
|
You can connect the scope inputs, via software, to any power line voltage or current - no need for dangerous probes! Every IPC graph can be instantly copied to the clipboard, ready for pasting into Microsoft Word or any other report writing program.
|
|
The meters in the Power Flow Option let you examine every important power flow parameter, real time.And the resettable min/max meters capture the lowest and highest values. There's even a kWh meter that measures the cost of electric power for the equipment that you're testing. |
|
Military and government agencies...
Military and government agencies use the Industrial Power Corruptor to test critical electronic systems. Typical standards include FAA G-2100G and MIL SPEC standards.
Compliance engineers and test labs...
Compliance engineers and test labs use the Industrial Power Corruptor to verify compliance with IEC standards, including IEC 61000-4-11 and 61000-4-34, and other national and international voltage sag immunity standards.
Teaching and Research Tool
IPC is a compact, portable (luggable) unit that combines complete data collection with safe design for use in laboratory or experimental conditions:All data provided in .CSV files that can be displayed and analyzed with the bundled software or can be viewed with other editors, such as Excel.
Once IPC is connected to AC power and equipment under test, all tests can be run from user-friendly front panel interface. There is no need to connect and disconnect voltage probes, current sensors, etc. Tests can be done both rapidly and safely with students of any experience level.
|
|
The Power Flow Analysis Option turns your Industrial Power Corruptor into a sophisticated, safe, and easy-to-use power analyzer. You get real time oscilloscopes, spectrum analyzers, vector scopes, harmonic meters, power flow meters, and more - all without dangerous current clamps and voltage probes. Optimized for industrial equipment, the Power Flow Analysis Option is perfect for complying with standards like SEMI E6. You can add the Power Flow Analysis Option at any time - all you need is an e-mailed password. ![]() Real-time oscilloscope and spectrum analyzer are automatically connected to any voltage or current channel.Quickly identify rectifier waveforms, flat-topping, harmonics, and more.![]() Record the energy consumption during your industrial processKnow where your power is going. Use the drop-down list at the top to see similar graphs for harmonics, power factor, peak current, kVARs, and more. Optimized for SEMI E6.![]() Real time metersIncluding min/max meters - are updated constantly in power flow mode.![]() Monitor every harmonicGrab the triplen harmonics, verify that harmonic filters are working properly, check compliance with standards. |
Voltage Sag Generator Highlights & Uses
- Voltage dips
- The IPC create sags/dips, swells, interruptions on 100V - 480V systems, at up to 480 volts and up to 200 amps continuous
- Evaluate the response of industrial equipment to power disturbances
- Measure energy consumption at all stages of a process or cycle
- Fully compliant with SEMI F47, IEC 61000-4-34, IEC 61000-4-11
- Design and test improvements for equipment
- Reengineer process flow to optimize energy use
- Certify compliance with a range of industry, domestic and international standards
- Microprocessor and semiconductor manufacturing
- Robotics
- Continuous process manufacturing (biotech, automotive, plastics...)
- Elevator and other large building controls
IPC Downloads
Application Notes, Manuals, and Technical Information
| File | Description | Format / Size |
| Current for sag-dip testing - Part 1.pdf | Part 1- Practical Current Requirements for Sag / Dip Immunity Testing - Experimental results for a standard test load. (Draft) |
271 KB |
| Current for sag-dip testing - Part 2.pdf | Part 2- Practical Current Requirements for Sag / Dip Immunity Testing - Practical analysis of a small adjustable speed drive (Draft) |
832 KB |
| Testing with IEEE 1100 _CBEMA_ Power Disturbances.pdf | Immunity Testing with IEEE 1100 (CBEMA) Power Disturbances |
432 KB |
| Industrial Power Corruptor Voltages.pdf | Precision Voltages from the PSL Industrial Power Corruptor - How to calculate precision output voltages |
117 KB |
| PSL IPC Rise and Fall time.pdf | PSL Industrial Power Corruptor: Rise and Fall Times per IEC 61000-4-34 and IEC 61000-4-11 |
401 KB |
| F47Mistakes.pdf | Common mistakes - sag testing |
515 KB |
| AN_2004-04-01 - PSL Industrial Power Corruptor - File Trigger.pdf | PSL Industrial Power Corruptor - File Trigger (Rev 1.01) |
149 KB |
|
PSL_Industrial_Power_Corruptor_4.0.0.zip Right click and select "Save Link As..." |
Industrial Power Corruptor Software (Rev 4.0.0) for computers running Microsoft© Windows® |
3.98 MB |
ChannelScopeII_308.zip | ChannelScope II Rev 3.0.8 |
1.02 MB |
| FlowScope_208.zip | FlowScope Rev 2.0.8 |
1.66 MB |
| Brochure - IPC 1.3.2.pdf | Industrial Power Corruptor Brochure |
582 KB |
| Industrial Power Corruptor User Manual 1.00 Rev.pdf | Industrial Power Corruptor Manual |
9,062 KB |
| F47-480V-50A_Manual.pdf | F47 Sag Generator (classic) Manual |
5,350 KB |
| Service / Calibration Manual - F47 Sag Generator | [contact factory] | N/A |
| Service / Calibration Manual - Industrial Power Corruptor | [contact factory] | N/A |
| PSL Intro to Voltage Sags | Short video clip demonstrating some common causes and misconceptions regarding voltage sags. |
21,043 KB |
| VIDEOofIPC.AVI | IPC demonstration - A short video clip demonstrating the IPC inducing a sag on a personal computer. |
37,685 KB |
| f47_connections.pdf | SEMI F47 connections - Application Note on power connections during SEMI F47 testing, with lots of useful photos and examples. |
2,271 KB |
| f47_gestures.pdf | Hand gestures for SEMI F47 testing - Application Note on PSL's standard hand gestures for SEMI F47 testing in noisy environments, such as clean rooms. |
254 KB |
| Sample_SEMI_F47_report.pdf | Sample SEMI F47 voltage sag immunity report - A typical test report for a typical piece of semiconductor fabrication equipment. |
221 KB |
| sola_sdn-4-24-100_f47_certificate.pdf | Sample SEMI F47 voltage sag immunity Certificate - A typical Voltage Sag Immunity certificate for a component. |
20 KB |
| "IOGear" USB to Serial Adapter Drivers | You can find drivers, manuals, and in-depth installation instructions for the IOGear USB to Serial Adapter on the manufacturers web site. |
524.85 KB |
Request a price quotation
IPC Specifications
Latest Software Rev 3.0.5 - Latest Firmware Rev 3.0.0
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||